Background

30KW 40KW 50KW Off Grid Single Phase Inverter

Professional R & D Team
We are a focus on manufacture of off-grid inverters team with professional R&D capabilities.

Strict Quality Control
We have strict quality control to ensure that each inverter passes the aging quality test before delivery.

Assured Service
We offer after-sales video guide maintenance,response within 24 hours.

  • DM
  • shandong, China
  • 15 days
  • 100pcs/month
  • Information
  • Download

Inverter

Single phase inverter

30KW inverter

1. Using IGBT from Mitsubishi company as the power components
2. Using American ATEMEL company microprocessor as digital controller
3. Perfect protection and warning functions
4. Circuit frame compact, Max. Efficiency≥9
5. With wide input voltage range
6. RS232/485/WIFI/GPRS communication

7. Tough screen English LCD, perfect display, interface-friendly

Inverter

            Single phase inverter30KW inverterInverter


Single phase inverter

30KW off grid single phase inverter technical parameters

Type

NB120-30KDZ

NB240-30KDZ

NB380-30KDZ

DC input

Input rated voltage

120 VDC

240 VDC

380 VDC

Input rated current

278 A

139 A

88 A

Input DC voltage range

100-155 VDC

200-310 VDC

320-496VDC

AC input

(AC Bypass)

Allow input voltage range

110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC

Input rated current

272A / 250A / 136 A /125A

Bypass transfer time

≤100 ms(Can be customized ≤4ms version)

AC output

Output rated power

30KW

Output rated voltage and frequency

110 VAC / 120 VAC / 220 VAC / 240 VAC50Hz / 60Hz

Output rated current

272A / 250A / 136 A /125A

Output voltage accuracy

110 VAC / 120 VAC / 220 VAC / 240 VAC± 1%

Output frequency accuracy

50Hz / 60Hz ±0.05%

Waveform distortion (THD).

≤3% (Linear load)

Dynamic response time
(Load 0←→100%)

2ms

Power factor (PF)

1

Overload capacity

120%,5 minutes200%,3 seconds

Crest factor (CF)

3:1

Inverter efficiency

94%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-20℃~+60℃

 Humidity

0~90%, No condensation

Altitude

6000m Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Equipped with isolated transformer

Yes

Pure Sine Wave

Yes

AC Charger

Available, optional

Solar Battery Charger

Available, optional

Dry Contact

Available. Optional

Size(mm)

800*600*2260mm

Weight(kg)

360kg


40KW off grid single phase inverter technical parameters

Type

NB192-40KDZ

NB240-40KDZ

NB380-40KDZ

DC input

Input rated voltage

192 VDC

240VDC

380 VDC

Input rated current

231 A

185 A

117 A

Input DC voltage range

160-248 VDC

200-310 VDC

320-496VDC

AC input

(AC Bypass)

Allow input voltage range

110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC

Input rated current

364A / 334A / 182A / 166A

Bypass transfer time

≤100 ms(Can be customized ≤4ms version)

AC output

Output rated power

40KW

Output rated voltage and frequency

110 VAC / 120 VAC / 220 VAC / 240 VAC50Hz / 60Hz

Output rated current

364A / 334A / 182A / 166A

Output voltage accuracy

110 VAC / 120 VAC / 220 VAC / 240 VAC ± 1%

Output frequency accuracy

50Hz / 60Hz ±0.05%

Waveform distortion (THD).

≤3%(Linear load)

Dynamic response time
(Load 0←→100%)

2ms

Power factor (PF)

1

Overload capacity

120%,5 minutes200%,3 seconds

Crest factor (CF)

3:1

Inverter efficiency

94%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-20~+60

Humidity

0~90%, No condensation

Altitude

6000m Higher than 2000m rated power should be reduced

Pure Sine Wave

Yes

Equipped with copper transformer

Yes

If solar charger is available

Yes

AC Charger

Optional

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Size(mm)

660*1300*1600mm

Weight(kg)

510kg


50KW off grid single phase inverter technical parameters

Type

NB240-50KDZ

NB380-50KDZ

DC input

Input rated voltage

240 VDC

380 VDC

Input rated current

231 A

146 A

Input DC voltage range

200-310 VDC

320-496VDC

AC input

(AC Bypass)

Allow input voltage range

110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC

Input rated current

455A / 417A / 227A /208A

Bypass transfer time

≤100ms(Can be customized ≤ 4ms version)

AC output

Output rated power

50KW

Output rated voltage and frequency

110 VAC / 120 VAC / 220 VAC / 240 VAC50Hz / 60Hz

Output rated current

455A / 417A / 227A / 208A

Output voltage accuracy

110 VAC / 120 VAC / 220 VAC / 240 VAC ± 1%

Output frequency accuracy

50Hz / 60Hz ±0.05%

Waveform distortion (THD).

≤3% (Linear load)

Dynamic response time
(Load 0←→100%)

2ms

Power factor (PF)

1

Overload capacity

120%,5 minutes200%,3 seconds

Crest factor (CF)

3:1

Inverter efficiency

94%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-20℃~+60℃

 Humidity

0~90%, No condensation

 Altitude

6000m Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Equipped with isolated transformer

Yes

Pure Sine Wave

Yes

AC Charger

Available, optional

Solar Battery Charger

Available, optional

Dry Contact

Available. Optional

Size(mm)

660*1300*1600mm

Weight(kg)

510kg


30KW inverter

Inverter

Single phase inverter

Company Style
Company elegant demeanour
Exhibition Activities
The meeting
business license
business license
9001
9001
Get the latest price? We'll respond as soon as possible(within 12 hours)
This field is required
This field is required
Required and valid email address
This field is required
This field is required
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.