30KW 40KW 50KW Off Grid Single Phase Inverter
Professional R & D Team
We are a focus on manufacture of off-grid inverters team with professional R&D capabilities.
Strict Quality Control
We have strict quality control to ensure that each inverter passes the aging quality test before delivery.
Assured Service
We offer after-sales video guide maintenance,response within 24 hours.
- DM
- shandong, China
- 15 days
- 100pcs/month
- Information
- Download
1. Using IGBT from Mitsubishi company as the power components
2. Using American ATEMEL company microprocessor as digital controller
3. Perfect protection and warning functions
4. Circuit frame compact, Max. Efficiency≥9
5. With wide input voltage range
6. RS232/485/WIFI/GPRS communication
7. Tough screen English LCD, perfect display, interface-friendly
30KW off grid single phase inverter technical parameters
Type | NB120-30KDZ | NB240-30KDZ | NB380-30KDZ | |
DC input | Input rated voltage | 120 VDC | 240 VDC | 380 VDC |
Input rated current | 278 A | 139 A | 88 A | |
Input DC voltage range | 100-155 VDC | 200-310 VDC | 320-496VDC | |
AC input (AC Bypass) | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | ||
Input rated current | 272A / 250A / 136 A /125A | |||
Bypass transfer time | ≤100 ms(Can be customized ≤4ms version) | |||
AC output | Output rated power | 30KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 272A / 250A / 136 A /125A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | |||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |||
Waveform distortion (THD). | ≤3% (Linear load) | |||
Dynamic response time | 2ms | |||
Power factor (PF) | 1 | |||
Overload capacity | 120%,5 minutes;200%,3 seconds | |||
Crest factor (CF) | 3:1 | |||
Inverter efficiency | 94% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -20℃~+60℃ | |||
Humidity | 0~90%, No condensation | |||
Altitude | <6000m Higher than 2000m rated power should be reduced | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with isolated transformer | Yes | |||
Pure Sine Wave | Yes | |||
AC Charger | Available, optional | |||
Solar Battery Charger | Available, optional | |||
Dry Contact | Available. Optional | |||
Size(mm) | 800*600*2260mm | |||
Weight(kg) | 360kg |
40KW off grid single phase inverter technical parameters
Type | NB192-40KDZ | NB240-40KDZ | NB380-40KDZ | |
DC input | Input rated voltage | 192 VDC | 240VDC | 380 VDC |
Input rated current | 231 A | 185 A | 117 A | |
Input DC voltage range | 160-248 VDC | 200-310 VDC | 320-496VDC | |
AC input (AC Bypass) | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | ||
Input rated current | 364A / 334A / 182A / 166A | |||
Bypass transfer time | ≤100 ms(Can be customized ≤4ms version) | |||
AC output | Output rated power | 40KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 364A / 334A / 182A / 166A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 1% | |||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |||
Waveform distortion (THD). | ≤3%(Linear load) | |||
Dynamic response time | 2ms | |||
Power factor (PF) | 1 | |||
Overload capacity | 120%,5 minutes;200%,3 seconds | |||
Crest factor (CF) | 3:1 | |||
Inverter efficiency | 94% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -20℃~+60℃ | |||
Humidity | 0~90%, No condensation | |||
Altitude | <6000m Higher than 2000m rated power should be reduced | |||
Pure Sine Wave | Yes | |||
Equipped with copper transformer | Yes | |||
If solar charger is available | Yes | |||
AC Charger | Optional | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Size(mm) | 660*1300*1600mm | |||
Weight(kg) | 510kg |
50KW off grid single phase inverter technical parameters
Type | NB240-50KDZ | NB380-50KDZ | ||
DC input | Input rated voltage | 240 VDC | 380 VDC | |
Input rated current | 231 A | 146 A | ||
Input DC voltage range | 200-310 VDC | 320-496VDC | ||
AC input (AC Bypass) | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | ||
Input rated current | 455A / 417A / 227A /208A | |||
Bypass transfer time | ≤100ms(Can be customized ≤ 4ms version) | |||
AC output | Output rated power | 50KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 455A / 417A / 227A / 208A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 1% | |||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |||
Waveform distortion (THD). | ≤3% (Linear load) | |||
Dynamic response time | 2ms | |||
Power factor (PF) | 1 | |||
Overload capacity | 120%,5 minutes;200%,3 seconds | |||
Crest factor (CF) | 3:1 | |||
Inverter efficiency | 94% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -20℃~+60℃ | |||
Humidity | 0~90%, No condensation | |||
Altitude | <6000m Higher than 2000m rated power should be reduced | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with isolated transformer | Yes | |||
Pure Sine Wave | Yes | |||
AC Charger | Available, optional | |||
Solar Battery Charger | Available, optional | |||
Dry Contact | Available. Optional | |||
Size(mm) | 660*1300*1600mm | |||
Weight(kg) | 510kg |