50KW 60KW 75KW 100KW Off Grid Three Phase Inverter
Professional R & D Team
We are a focus on manufacture of off-grid inverters team with professional R&D capabilities.
Strict Quality Control
We have strict quality control to ensure that each inverter passes the aging quality test before delivery.
Assured Service
We offer after-sales video guide maintenance,response within 24 hours.
- DM
- shandong, China
- 15 days
- 100pcs/month
- Information
- Download
1. using IGBT from Mitsubishi company as the power components
2. using American ATEMEL company microprocessor as figure controller
3. perfect protection and warning functions
4. circuit frame compact, Max. Efficiency≥94%
5. with wide input voltage range
6. RS232/485 communication, multi communication interface can be selected
7. big-screen English LCD, perfect display, interface-friendly
50KW Off Grid Three Phase Inverter Technical Parameters
Type | NB480-50KSZ | NB380-50KSZ | |
DC input | Input rated voltage | 480 VDC | 380 VDC |
Input rated current | 115 A | 146 A | |
Input DC voltage range | 400-620 VDC | 320-496VDC | |
AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 139A / 76A / 72.5A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 50KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 139A / 76A / 72.5A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time | 2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20℃~+60℃ | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 660*1300*1600mm | ||
Weight(kg) | 450kg |
60KW Off Grid Three Phase Inverter Technical Parameters
Type | NB380-60KSZ | NB480-60KSZ | |
DC input | 220 VDC | 380 VDC | 480 VDC |
68 A | 175 A | 139 A | |
180-300 VDC | 320-496VDC | 400-620 VDC | |
AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 153.6A / 91A / 86A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 60KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 153.6A / 91A / 86A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time | 2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20℃~+60℃ | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 750*1500*1700mm | ||
Weight(kg) | 680kg |
75KW Off Grid Three Phase Inverter Technical Parameters
Type | NB380-75KSZ | NB240-75KSZ | |
DC input | Input rated voltage | 380 VDC | 240 VDC |
Input rated current | 219 A | 347 A | |
Input DC voltage allowing range | 320-496 VDC | 200-310 VDC | |
AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 192A /114A / 108A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 75KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 192A /114A / 108A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time | 2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20℃~+60℃ | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 750*1500*1700mm | ||
Weight(kg) | 680kg |
100KW Off Grid Three Phase Inverter Technical Parameters
Type | NB360-100KSZ | NB380-100KSZ | |
DC input | Input rated voltage | 360 VDC | 380 VDC |
Input rated current | 309 A | 292 A | |
Input DC voltage range | 300-465 VDC | 320-496VDC | |
AC input (AC Bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 278A / 152A / 145A | ||
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
AC output | Output rated power | 100KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 278A / 152A / 145A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) | 2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20℃~+60℃ | ||
Humidity | 0~90%,No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | Product Size: 650*1400*1500 | Package Size: 750*1500*1700 | |
Weight(kg) | 730kg |