Deming FKJ-GT 20KW MPPT on grid wind turbine controller with dump load
On Grid Wind Turbine System
The On grid wind turbine system is composed of wind turbine, on grid controller, on grid inverter,metering device, and power distribution system. Wind energy is converted into AC electrical energy by the wind turbine, and then converted into DC electrical energy by the on grid controller, and then DC electrical energy is converted into AC electrical energy of the same frequency and phase as the grid by the on grid inverter, and part of the power is supplied to the local load. Surplus power is fed into the grid.
- Deming
- china
- 7 days
- 1000 pcs
- Information
Technical Parameters of the On Grid Wind Turbine Controller 20KW
Type | FKJ-GT 20KW |
Wind turbine rated power | 20KW |
Wind turbine Max. power | 40KW |
Wind turbine rated voltage | AC220V |
Function | Rectifier,control, DC output |
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester |
Manual function | Manual brake, reset, emergency switch |
Display mode | LCD |
Display content | Wind turbine voltage, current, power; DC output voltage, DC output current, DC output power, total power. |
PWM constant voltage | ≥350dc |
wind turbine 3-phase dump load voltage | 380±5Vdc |
Time-lapse of the wind turbine 3-phase dump load | 12-20 min |
PWM dump load fuse | 80A |
Fuse of DC output | 100A |
Work environment temperature | -30-60°C |
Relative humidity | <90% No condensation |
Noise (1m) | <40dB |
Degree of protection | IP20(Indoor) |
Cooling method | Forced air cooling |
*Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet |
Size of the controller (mm) | 760*600*335 |
Weight of the controller | 45Kg |
Size of the dump load (mm) | 943*795*415 |
Weight of the dump load | 73Kg |
*Above parameter only for reference
1. Could be custom made to user specifications.
2, Could have solar power control subject to user demand.
Type | FKJ-GT1.5KW | FKJ-GT2KW | FKJ-GT3KW | |
Wind turbine rated power | 1.5KW | 2KW | 3KW | |
Wind turbine Max. power | 3KW | 4KW | 6KW | |
Wind turbine rated voltage | AC220V | AC220V | AC220V | |
Solar panels power (optional) | 300W | 600W | 900W | |
Function | Rectifier,control,DC output | |||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | |||
Manual function | Manual brake, reset, emergency switch | |||
Display mode | LCD | |||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | |||
PWM constant voltage | ≥320dc | ≥320dc | ≥320dc | |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 350±5Vdc | 350±5Vdc | |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | |
Solar panels fuse | 2A | 3A | 4A | |
PWM dump load fuse | 10A | 10A | 16A | |
Fuse of DC output | 16A | 16A | 20A | |
Work environment temperature | -30-60°C | |||
Relative humidity | <90% No condensation | |||
Noise (1m) | <40dB | |||
Degree of protection | IP20 (Indoor) IP65 (Outdoors) | |||
Cooling method | Forced air cooling | |||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | |||
Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 510*360*240 | |
Weight of the controller | 15Kg | 17Kg | 17Kg | |
Size of the dump load (mm) | 410*360*120 | 410*360*120 | 400*410*250 | |
Weight of the dump load | 7Kg | 9Kg | 13Kg |
Type | FKJ-GT5KW | FKJ-GT5KW | FKJ-GT10KW | |
Wind turbine rated power | 5KW | 5KW | 10KW | |
Wind turbine Max. power | 10KW | 10KW | 20KW | |
Wind turbine rated voltage | AC220V | AC380-400V | AC380-400V | |
Solar panels power(optional) | 1.5KW | 1.5KW | 3KW | |
Function | Rectifier,control,DC output | |||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | |||
Manual function | Manual brake, reset, emergency switch | |||
Display mode | LCD | |||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | |||
PWM constant voltage | ≥320dc | ≥520dc | ≥520dc | |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 540±5Vdc | 540±5Vdc | |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | |
Solar panels fuse | 5A | 5A | 8A | |
PWM dump load fuse | 25A | 16A | 32A | |
Fuse of DC output | 32A | 20A | 40A | |
Work environment temperature | -30-60°C | |||
Relative humidity | <90% No condensation | |||
Noise (1m) | <40dB | |||
Degree of protection | IP20(Indoor) IP65 (Outdoors) | |||
Cooling method | Forced air cooling | |||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | |||
Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 580*400*240 | |
Weight of the controller | 18Kg | 18Kg | 23Kg | |
Size of the dump load (mm) | 600*450*380 | 600*450*380 | 690*450*530 | |
Weight of the dump load | 28Kg | 28Kg | 35Kg |