Hydro Generator Controller RS485
Off-Grid PWM Hydroelectric Generator Controller
FKJ-B model Off Grid PWM Hydroelectric Generator Controller Product Characteristics
◆The product is manufactured according the JB/T6939.1-2004 industrial standard and GB/T 19115.1-2003 national standard also with users’ technical requirements.
◆Big LCD display. The images tell working state visually. Various data show: real-time generator voltage, current, power; battery group voltage, charge current.(The main board is with button battery, in case of power failure, history data can be saved for 30 days)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆When the battery disconnect or damage, the three-phase dump load will start automatically to avoid the gengerator idling and runaway accident.
◆The protection function of battery: polarity reverse protection, disconnection and damage protection.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆The controller is equipped with surge arrester.
※ Solar panel control system is optional. Based on customers' requirement.
※ Disel generator port is optional. Control the generator start and stop automatically
※ Adopt Modbus Communication protocol. Convenient to carry out the secondary development.
※ Adjusting the technical specification via RS485 is available. Convenient to adjust the different wind turbines for professional customers.
※ Support WIFI and GPRS. Customers can monitor the real-time working state of the generator system via PC and mobile and query history working sate. Both Android and OS are compatible in Mobile.
- DM
- shandong, China
- 3 days
- 300pcs/month
- Information
- Video
- Download
Technical parameters of off grid hydroelectric generator controller 10KW
Type | 10KW-120Vdc | 10KW-220Vdc | 10KW-240Vdc |
Hydroelectric generator | 10KW | 10KW | 10KW |
Hydroelectric generator | 20KW | 20KW | 20KW |
*Solar panel power | 3KWp | 3KWp | 3KWp |
Battery | 120Vdc | 220V | 240V |
Function | Rectifier,charge, control, *DC output | ||
Automatic protection function | Over voltage protection, constant voltage charge, arrester | ||
Manual function | Manual brake | ||
Display mode | LCD+LED | ||
Display content | Hydroelectric generator voltage, current, power;battery voltage, charge current | ||
PWM constant pressure voltage | >145Vdc | >260Vdc | >290 Vdc |
3-phase dump load voltage | 150±2Vdc | 270±2Vdc | 300±5Vdc |
Recharge voltage | 135±2Vdc | 245±2Vdc | 280±5Vdc |
Self-provided battery connecting wire | >12mm² | >18mm² | >12mm² |
PWM fuse | 125A | 80A | 63A |
Charging fuse | 160A | 120A | 100A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor)IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
*Extral Control function (optional) | Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake | ||
*Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Controller Size (mm) Weight (kg) | 580*400*240 24 Kg | 580*400*240 24Kg | 580*400*245 24Kg |
Dump load Size (mm) Weight (kg) | 700*450*530 37 Kg | 700*450*530 37Kg | 700*450*530 37Kg |
*Above parameter only for reference. Could be custom made to user specifications.